The double throw relay allows for wiring to interrupt the system and to sound an alarm by others when moisture is detected. The wiring diagrams are very route the cable from the wet switch.

Franklin Electric Hvac Accessories Hvac Parts
Wet switch ws 1 wiring diagram. Use with the wet switch sos condensate cop cp 22 all types and all float switches on 24vac control circuits. One or two drops will cause wet switch to turn off a unit alerting a serviceman to a moisture problem. The wet switch is designed to interrupt the operation of cooling systems. Route the cable from the wet switch to cooling control voltage transformer as shown in the wiring diagram. Ws 1 wet switch. Detailed and large wiring diagrams are on the motor and the motor carton and also in the installation and safety instruction sheet.
Wet switch flood detector. Diversitech ws 1 wet switch flood detector instructions pdf 813 kb reviews. Get expert assistance from our team. The installation instructions provided with the diversitech ws 1 wet switch. A lit led indicates the wet switch is activated and has turned the unit off. Restore power to the system.
Diversitech ws 1 wet switch flood detector the wet switch flood detector is a solid state control designed to help prevent flooding damage to carpets walls furniture ceilings etc. Cut common wire of transformer. Connect green wire from wet switch to common wire that was cut from transformer in step 4. Connect wiring as shown in the diagrams on page 2. Diversitech ws 1 wet switch flood detector double throw relay allows for wiring to interrupt system and to sound an alarm by others when moisture is detected. Button until service is obtained however a red trouble led will remain lit.
Dec 03 how to reset float switch. It turns the system off when moisture due to condensate or drain leaks is detected. Call our product specialists at 800 865 5931. Controlling selected components system components such as compressors electric valves condenser model no. Wires may be extended as necessary but avoid excess run lengths. Place wet switch padded side down on the surface to be monitored.
Thank you for a better wiring diagram then the original in the. If an alarm condition exists the homeowner can turn the alarm off with a insilencein. Connect black wire from wet switch to same wire on transformer where common was cut. It now has a built in test and reset button for easier installation. Sun 9a 3p mon thu 7a 7p fri 7a 6p sat 9a 3p ct. Wire can be extended if necessary.