16112018 16112018 3 comments on notifier fcm 1 wiring diagram. Page 5 wiring diagrams this page.
Notifier Cmx 2 Addressable Control Module
Notifier fcm 1 rel wiring diagram. The fcm 1 rel module must be programmed with the correct releasing type code listed in the nfs 320ec programming manual. Surface mounted electrical boxes smb500 are available. Connecting a releasing device to the fcm 1 rel. Connecting a releasing device to a fcm 1 module connecting an. Notifier nfse manual online. The fcm 1 rel releasing control module uses a redundant protocol.
Ing power limited and non power limited wiring in the same junction box as fcm 1a. Maximum slc current draw. 65 ma led on temperature range. Releasing applications c limited energy cable cannot be used to wire a. 5 for frm 1 general fcm 1 control module the fcm 1 addressable control module provides notifier intelligent control pan els a circuit for notification appliances horns strobes speak ers etc or to monitor a telephone circuit. It reveals the parts of the circuit as streamlined forms and the power as well as signal links in between the tools.
Mounting the fcm 1 mounts directly to 4 square electrical boxes see figure 2a. All wiring shown is supervised and power limited. Any number of ul listed contact closure devices may be used. For installation instructions see the following documents. 15 to 32 vdc. It will then enter a 3 second window awaiting a pair of confirmation signals.
Notifier slc wiring manual document 51253. 32f to 120f 0c to 49c dimensions. 4675 h x 4275 w x 14 d mounts to a 4 square by 218 deep box specifications for frm 1. Current rating maximum voltage load description application. If using the on board nacs see circuit requirements for section 474 connecting a releasing device to the control panel on page 44. The module must be armed with a pair of signals in order to activate.
All wiring must conform to applicable local codes ordi. Compatible notifier system control panels only list available from notifier. Maximum slc current draw. Variety of notifier fcm 1 wiring diagram. Install contact closure devices per manufacturers installation instructions. If no confirmation is received the module will automatically reset.
Frm 1a installation document i56 3502. Fmm 1 connect modules to listed compatible notifier control panels only. 15 to 32 vdc. The box must have a minimum depth of 218. The box must have a minimum depth of 21 8. Notifier fcm 1 wiring diagram.
Mounting the frm 1 mounts directly to 4 square electrical boxes see fig ure 2a. Notifier nfs manual online. Dn 6724 040504 page 1 of 4 fcm 1 module see wiring diagram fig. All wiring must conform to applicable local codes ordi. Compatible notifier system control panel list available from noti fier. Surface mounted electrical boxes smb500 are available from notifier.
Fcm 1a installation document i56 1169. A wiring diagram is a simplified conventional pictorial representation of an electric circuit.