A wiring diagram is a simplified conventional pictorial representation of an electric circuit. Fzm 1 zone interface monitor module.
Wiring Diagram Manual Pdf Landing Gear Switch
Frm 1 wiring diagram. Maximum slc current draw. 32f to 120f 0c to 49c dimensions. Set the address on the module per job drawings. Class a supervised wiring to the monitored device. When using control modules in. Typical notification appliance circuit configuration nfpa style y.
Maximum slc current draw. The fcm 1a is configured for a single class b style y or class a style z notification appliance circuit. Install contact closure devices per manufacturers installation instructions. Surface mounted electrical boxes smb500 are available from notifier. Any number of ul listed contact closure devices may be used. Connect modules to listed compatible notifier control panels only.
The frm 1 relay control module is intended for use in intelligent two wire systems where the individual address of each module is selected using the built in rotary switches. Module polarities are shown in alarm. Module mounting with barrier. A78 2611 11 a78 2610 08 specifications normal operating voltage. Transmits the status of one zone of 2 wire detectors to the fire alarm control panel. 65 ma led on temperature range.
Relay module wiring diagram. It reveals the parts of the circuit as streamlined forms and the power as well as signal links in between the tools. Fmm 1 connect modules to listed compatible notifier control panels only. Removing general description rotary switch stop. The frm 1a provides two form c dry contacts that switch together. It allows a compatible control panel to switch discrete contacts by code command.
Page 5 wiring diagrams this page. Removing rotary switch stop. 15 to 32 vdc. All wiring shown is supervised and power limited. Typical fault tolerant notification appliance circuit configuration nfpa style z. Install module wiring in accordance with the job drawings and appropriate wiring diagrams.
All wiring shown is supervised and power limited. 65 ma led on. The power limited wiring must be placed into the isolated quadrant of the module barrier figure 2b. Secure module to electrical box supplied by installer see figure 2a. 15 to 32 vdc maximum current draw. Install module wiring in accordance with the job drawings and appropri ate wiring diagrams.
Page 1 figure 1. Class b supervised wiring to the monitored device. Smaller size fits inside devices or junction boxes. The frm 1 mounts directly to 4 square electrical boxes see fig ure 2a. All wiring must conform to applicable local codes ordi nances and regulations. Fmm 101 mini monitor module.
4675 h x 4275 w x 14 d mounts to a 4 square by 218 deep box specifications for frm 1. 15 to 32 vdc. The box must have a minimum depth of 21 8. Operation each fcm 1a or frm 1a uses one of 159 possible module addresses on a slc loop 99 on clip loops. Variety of notifier fcm 1 wiring diagram.